Mecanum’s 2 microphones impedance tubes are specifically designed to measure the main normal indicators of a wide range of acoustical materials. The method is based on ASTM E1050 and ISO 10534-2 standards.
**Large spacing between µ1 and µ2 is essential for better results at low frequencies (as stated in ASTM E1050)
![]() |
![]() |
![]() |
![]() |
MATERIAL PROPERTIES
➡ Normal incidence sound absorption coefficient (α)
➡ Normal incidence complex reflection coefficient (R)
➡ Normal surface impedance (Zs)
TUBE SPECIFICATIONS
Tube Internal Diameter | Frequency Range | High SPL Option |
29 mm | 200-6600 Hz | Available |
44.44 mm | 100-4300 Hz | N/A |
100 mm | 35-1900 Hz | N/A |
TUBE-X SOFTWARE
TUBE-X is a user-friendly software that will simplify the measurement procedure. It’s also fully compatible with FOAM-X software that can extract non-acoustic parameters of porous materials using the inverse method with a 2 microphones absorption measurement.
ADDITIONAL INFORMATIONS
- All Mecanum impedance tubes are delivered with grids (for low mechanical strength samples) and rings (to avoid leaks).
- All Mecanum’s 2 microphones impedance tubes can be upgraded to 3 or 4 microphones, contact your Mecanum product expert for details.
Main advantages of the product
![]() |
Measurement method in accordance with the ASTM and ISO standards; |
![]() |
User-friendly interface; |
![]() |
Measurement method from the scientific literature; |
![]() |
Superior manufacturing quality. |
Other Mecanum’s Related Products
![]() |
![]() |
![]() |
![]() |
|
Grids and rings | Porous material slicer | Circular cutter | Resistive screen and fabric holder | |
![]() |
![]() |
![]() |
![]() |
![]() |
Enviro Weather station | Anechoic Termination | FOAM-X | Digital Piston | NOVA |